ClairHydra hydro-pneumatic pump system

Pump Systems

Hydro-pneumatic pump systems sized to your site's real head, flow, and duty cycle — not a one-size-fits-all unit.

Book Your Free Site Assessment

Why ClairHydra Pumps

Engineered for Real Building Demand, Not a Nameplate

Constant-Pressure Delivery

VFD-controlled models match motor speed to real-time demand for steadier delivered pressure than fixed-speed operation.

Reduced Hydraulic Shock

VFD's smooth ramp-up avoids the instant-on surge of fixed-speed starting, easing stress on pipework and fittings.

Stainless Steel Hydraulics

SS304/SS316 hydraulic options resist corrosion across a range of water conditions and applications.

Configurable Motor Protection

Dry-running, phase-loss, and electrical overload protection available as optional, site-configured additions — not standard on every unit.

1.00–1.50 HP

Motor Power Range

IE2/IE3

Continuous-Duty, Two-Pole Motor Class

IP55

Motor Protection Rating

Technical Specifications

Pump Series, Model by Model

Every figure below is copied directly from the verified CMI 4 performance datasheet — nothing rounded, nothing estimated.

View Full Technical Specifications

Model Specifications

Model Motor Power Motor Class Protection Pump Body Hydraulics Control Tank Power Input G1 Port Warranty
CHPUMP-1HP-4-4 1.00 HP Continuous-duty, two-pole IE2/IE3 motors IP55, Class F insulation SS304 / CI-SS304 SS304 / SS316 Fixed speed or VFD 24 L Single phase 1¼" BSPF 1 year standard*
CHPUMP-1.5HP-4-6 1.50 HP Continuous-duty, two-pole IE2/IE3 motors IP55, Class F insulation SS304 / CI-SS304 SS304 / SS316 Fixed speed or VFD 100 L Single or three phase 1¼" BSPF 1 year standard*

Pump Body and Hydraulics materials come from different parts of the source spec sheet (the System Selection Snapshot table vs. the Features section), which don't fully agree with each other on material options — shown exactly as each section states, not reconciled into one figure.

Performance Curve — CMI 4 Series

Model 1.0 m³/h 1.5 m³/h 2.0 m³/h 2.5 m³/h 3.0 m³/h 3.5 m³/h 4.0 m³/h 4.5 m³/h 5.0 m³/h 5.5 m³/h 6.0 m³/h
CHPUMP 1HP-4-4 — H (m), P2 0.75 kW 38 37 36 34 33.5 32 30 28 27 24 20
CHPUMP 1.5HP-4-6 — H (m), P2 1.30 kW 56.5 55 54 53 52.5 51 49 45 44 42 36

H = head, in meters, at the given flow rate. Performance data based on water at 20°C, 50Hz — validate against actual head, flow, and NPSH requirements before final selection.

*Warranty covers manufacturing defects on non-consumable parts only; extended coverage terms set by the authorized dealer.

Site Assessment

What We Assess Before Sizing Your Pump

A pump spec sheet alone can't size your system — it depends on data specific to your building. This is what the free site assessment gathers before any quotation.

Required flow rate and peak demand pattern

Static head, friction losses, and required terminal pressure

Number of floors/outlets and diversity factor

Available power supply, duty cycle, and application criticality

Book Your Free Site Assessment