Commercial RO

Engineering Purity. Delivering Commercial RO Performance.

Commercial-grade reverse osmosis systems engineered for salt rejection up to 98%, recovery up to 60%, and dependable operation across real Indian water conditions.

Site-specific sizing, structured deployment, and lifecycle support.

Clairhydra commercial RO system

The Reality

Facilities lose money in three predictable ways.

Unstable Feed Water.

Variable raw-water quality directly affects output purity, operating stability, and downstream process confidence.

Low-Recovery Design.

Poorly engineered systems waste water and push avoidable operating cost into every month of production.

Opaque Specifications.

Many systems quote performance without defining operating limits, component pedigree, or deployment conditions.

The Clairhydra Standard

A transparent RO solution, not a brochure claim.

Clairhydra Commercial RO is built around engineering logic: defined input analysis, known component selection, measurable performance, and deployment matched to the actual site profile.

What this means for your site

You get a system whose operating expectations can be traced back to raw-water analysis, capacity planning, recovery targets, duty cycle, and pre-treatment discipline—so your team can plan, audit, and scale with confidence.

Warranty Support

1 Year Standard Warranty on all non-consumable components + 1 Year Extended Warranty.

Component Pedigree

Pentair jumbo Housing with Bypass is positioned as the pre-filtration platform.

Operating Boundaries

Automatic sand filter is mandatory for input TDS above 1000 PPM. Recommended duty cycle: up to 6 hours.

Performance Advantages

Built for purity, recovery, and operational confidence.

These are the commercial performance parameters that matter most on site: rejection, recovery, input discipline, and structured deployment.

Up to 98% Salt Rejection.

Positioned for high-purity commercial output where consistent water quality is a real operating requirement.

Up to 60% Recovery.

Engineered recovery performance helps reduce water loss versus inefficient or poorly matched systems.

Pentair Pre-Filtration Platform.

Pentair jumbo Housing with Bypass strengthens technical confidence in the pre-filtration stage.

Defined Input Envelope.

Input TDS and hardness must be reviewed up front so the installed system performs within a realistic operating boundary.

Duty Cycle: Up to 6 Hours.

The system is positioned with a defined operating cycle rather than vague all-day performance claims.

Structured Warranty Coverage.

Standard and extended warranty support reinforce the brand’s engineered, lifecycle-led commercial positioning.

Product Range

Choose the RO system path that fits your demand.

The Clairhydra Commercial RO range is structured to serve different output requirements while preserving engineering discipline.

CH125RO

Indicative output: 125 LPH

Suitable for smaller commercial applications that need dependable purity with defined operating boundaries.

View Specs

CH250RO

Indicative output: 250 LPH

A practical step-up for hospitality and institutional demand where output quality and daily stability both matter.

View Specs

CH500RO

Indicative output: 500 LPH

Built for heavier commercial demand where recovery, input discipline, and predictable performance are important.

View Specs

CH1000RO

Indicative output: 1000 LPH

Designed for larger installations that require stronger output capability with site-specific engineering review.

View Specs
Clairhydra RO system architecture diagram

System Architecture

How the Clairhydra RO solution works on site.

The system journey starts with raw-water understanding and moves through pre-treatment, controlled purification, recovery planning, and operating support.

1. Feed Water Analysis

Input profile is defined through TDS, hardness, pH, daily demand, and expected purity outcome before model selection.

2. Pre-Filtration & Protection

Pentair jumbo Housing with Bypass supports the pre-filtration stage, and an automatic sand filter becomes mandatory above 1000 PPM input TDS.

3. RO Purification & Recovery

The membrane stage is aligned to commercial purity targets, salt rejection up to 98%, and recovery performance up to 60%.

4. Operating Envelope & Support

Duty cycle, commissioning, and warranty-backed lifecycle planning complete the deployment logic.

Technical Specifications

Commercial RO operating parameters.

The table below consolidates brochure-backed commercial RO parameters referenced for this range. Final model selection must always be matched to actual raw-water analysis, site duty cycle, and application need.

Clairhydra Commercial RO operating parameter summary
Parameter Commercial RO Reference Engineering Note
Model Range CH125RO / CH250RO / CH500RO / CH1000RO Product path should be matched to site demand and raw-water profile.
Indicative Output Range 125 LPH to 1000 LPH Use actual daily demand and peak load for final sizing.
Salt Rejection Up to 98% Performance depends on feed water condition and final system design.
Recovery Up to 60% Recovery should be validated against water analysis and operating requirement.
Max Input TDS Up to 2000 PPM Brochure-referenced commercial limit; final acceptability remains site-specific.
Max Input Hardness Up to 1000 PPM Input hardness must be reviewed before final system configuration.
Recommended Duty Cycle Up to 6 Hours Commercial planning should respect the defined operating cycle.
Pre-Filtration Platform Pentair jumbo Housing with Bypass Used to strengthen pre-filtration discipline and component trust.
Mandatory Pre-Treatment Note Automatic sand filter required above 1000 PPM input TDS This boundary should be reviewed before quote finalization.
Warranty 1 Year Standard on non-consumables + 1 Year Extended Consumables are excluded from standard component warranty language.

Implementation

Institutional deployment process.

We do not position RO as a box sale. We deploy it as a structured site solution—from technical audit to lifecycle support.

Start Audit Process

Technical Audit

Collection of water analysis data, hardness, pH, TDS, and demand definition for system selection.

Engineering Sizing

Capacity, recovery, and operating boundaries are aligned to the site’s usage pattern and water profile.

Commissioning

Installation, startup, and operating validation are carried out to match actual site performance requirements.

Lifecycle Support

AMC planning and warranty-backed service logic help preserve output quality, system reliability, and membrane life.

FAQ

Technical clarifications buyers usually ask first.

These answers are structured around the practical commercial questions that matter before finalizing an RO system.

How is the right RO system size selected?

Model selection should be based on raw-water TDS, hardness, pH, daily demand, peak usage period, required purity, and the site’s recommended operating cycle.

What input water limits should be reviewed before ordering?

Commercial RO evaluation should review input TDS and hardness up front. The brochure-backed commercial reference includes input TDS up to 3000 PPM and hardness up to 1000 PPM, subject to final site review.

When is additional pre-treatment mandatory?

An automatic sand filter is mandatory where input TDS is above 1000 PPM. Pentair jumbo Housing with Bypass is positioned as the pre-filtration platform in the system logic.

What purity and recovery performance can be expected?

The commercial RO range is positioned around salt rejection up to 98% and recovery up to 60%, subject to feed-water profile, final engineering, and site operating conditions.

What duty cycle should be planned for this system?

The recommended operating cycle referenced for the range is up to 6 hours. Final planning should still reflect actual site demand and operating discipline.

What does the warranty include?

Warranty coverage is positioned as 1 Year Standard Warranty on all non-consumable components, plus 1 Year Extended Warranty. Consumables are not part of the non-consumable component warranty.

Next Step

Book a site assessment for the right RO recommendation.

Share your raw-water profile, output requirement, and site use case. We will help align the right Clairhydra Commercial RO path and determine your expected ROI from engineered recovery of up to 60%.